(20) Outdoor fan control at overload
(a)
Cooling
(i) Starting condition
When the outdoor air temperature (Tho-A) has risen higher than 41°C for 30 seconds continuously while the compressor is operating.
(ii) Contents of control
The outdoor fan is stepped up by 3 speed. (Upper limit 6th speed)
(iii) Reset condition
When the compressor is turned off or the outdoor air temperature (Tho-A) has dropped lower than 40°C.
(b)
Heating
(i) Starting condition
When the outdoor heat exchanger temperature (Tho-R) has risen higher than 13°C for 30 seconds continuously while
the compressor is operating.
(ii) Contents of control
The outdoor unit fan is stepped down by 3 speed. (Lower limit is 2nd speed)
(iii) Reset condition
When the compressor is turned off or the outdoor heat exchanger temperature (Tho-R) has dropped lower than 10°C.
Lower
L
Outdoor air temperature > 16˚C
Outdoor air temperature > 16˚C
Outdoor air temperature < = 16˚C
Outdoor air temperature < = 16˚C
temperature
high pressure sensor (HPS) is 2.72MPa
Tho-A
Tho-A
Tho-A
Normal operation
OFF
Outdoor air temperature(ºC)
Normal operation
OFF
Normal operation
OFF
Outdoor air temperature(ºC)
Outdoor heat exchanger temperature(ºC)
Normal operation
OFF
Outdoor heat exchanger temperature(ºC)
Lower limit speed
Lower limit speed
3rd
Tho-R
37
2.72MPa
Tho-R
37
(
)
Under control
ON
40
41
Under control
ON
Under control
ON
40
41
10
13
Under control
ON
10
13
197
-
-
'16 • SCM-T-199
high pressure sensor 1.50MPa - 2.72
high pressure sensor is higher than

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents