Fronius Selectiva 2100 Service Manual page 98

Table of Contents

Advertisement

Available languages

Available languages

524
525
526
527
529
530
531
532
Status codes in the event of a device fault / control system:
540
541
542
543
98
Cause: Secondary reference voltage outside the tolerance
Remedy:
-
Replace P-control
Cause: Current offset
Remedy:
-
Replace P-control
Cause: Current offset
Remedy:
-
Replace P-control
Cause: Overcurrent at primary power module
Remedy:
-
Check/change secondary diodes
-
Replace primary power module
-
Replace P-control
Cause: No secondary communication available
Remedy:
-
Replace P-control
Cause: No primary communication available
Remedy:
-
Check power module ribbon cable
-
Update software version
-
Replace P-control
-
Replace primary power module
Cause: Secondary EEPROM faulty
Remedy:
-
Replace P-control
Cause: C error
Remedy:
-
Update firmware version
-
Replace P-control
Cause: CFM PC board missing/faulty
Remedy:
-
Check CFM PC board plug connection
-
Replace P-control
-
Replace CFM PC board -> contact Technical Support team
Cause: No secondary communication
Remedy:
-
Replace P-control
Cause: Secondary initialisation failed
Remedy:
-
Check power module ribbon cable
-
Update software version
-
Replace P-control
Cause: Program/memory fault in characteristic control
Remedy:
-
Update firmware version
-
Replace P-control