Fronius Selectiva 2100 Service Manual page 97

Table of Contents

Advertisement

Available languages

Available languages

503
Cause: Primary overtemperature
Remedy:
-
Check device location/ambient temperature
-
Check for dirt
504
Cause: Fan jammed/faulty
Remedy:
-
Check for dirt
-
Replace fan
-
Replace primary power module
505
Cause: Intermediate circuit undervoltage or overvoltage
Remedy:
-
Replace primary power module
506
Cause: Asymmetric intermediate circuit
Remedy:
-
Replace primary power module
507
Cause: Primary supply voltage outside the tolerance
Remedy:
-
Remove the power module ribbon cable and check the 24 V supply:
OK = Replace P-control
Not present = Replace primary power module
508
Cause: Power failure (not the same as phase failure)
Remedy:
-
Check mains, mains cable and mains connection
509
Cause: Wrong device configuration
Remedy:
-
Check hardware (primary power module, CFM)
-
Software update
-
Return device
510
Cause: Primary EEPROM faulty
Remedy:
-
Replace primary power module
Status codes in the event of device fault / secondary circuit:
520
Cause: Secondary temperature sensor faulty
Remedy:
-
Replace secondary temperature sensor
-
Replace P-control
521
Cause: Secondary overtemperature
Remedy:
-
Check device location/ambient temperature
-
Check for dirt
522
Cause: Output fuse faulty (polarity reversal)
Remedy:
-
Check wiring
-
Replace output fuse
-
Check/change secondary diodes
-
Replace P-control
523
Cause: Secondary supply voltage outside the tolerance
Remedy:
-
Remove the power module ribbon cable and check the 16 V supply
OK = Replace P-control
Not present = Replace primary power module, replace P-control