(10)
Correctly thread the transformer
2
(4)
connection (3) and the inductor
connection (2)
Now fully insert the primary power mo-
3
dule and position it correctly
Insert the axial fan (5) in the strain-re-
4
lief device provided and connect it to
the primary power module
Establish the ribbon cable connection
5
(4) to the P-control
Fit the primary power module with five
6
5x10 TX25 tapping screws (1)
[3 Nm]
Fit the transformer connection with
7
three 5x10 TX25 tapping screws (3)
[4.5 Nm]
Fit the inductor connection with one
8
5x10 TX25 tapping screw (2)
[4.5 Nm]
Make sure the inductor leads are laid
9
parallel and bind them with two type
200 cable ties (10)
Fit the primary power module supply
10
(L1, L2, L3, N) to the mains terminal
[1.5 Nm]
In case the assembly aid has been
11
mounted, remove it
Fit the front panel and the AC connec-
12
ting plate (see the "Closing the device"
section)