(1)
(2)
(2)
(1)
(1)
(2)
(2)
The ten 4x9 TX20 tapping screws (2)
(3)
(2)
5
are used to fit the busbar, the contact
rails, the temperature sensor and the
capacitor module
[1.5 Nm]
Additionally secure the busbar with a
6
PT5x25 TX25 screw (3)
[1.5 Nm]
Screw fitting (1):
-
M6x16 hexagon bolt (5)
-
M6 brass washer (6)
-
M6 lock washer (7)
Fit the transformer leads and fuse with
5
four M6x16 hexagon bolts (1)
[10 Nm]
1
Fit the transformer connection lid
6
Fit the front panel (see the "Closing the
(5)
7
housing" section)
(6)
(7)
Device type Diodes
2100 / 2120 /
2140 / 2160 /
2180 / 2200 /
4060 / 4075 /
4090 / 4120 /
4140 / 4160
8040 / 8060 /
8075 / 8090
8120 / 8140 /
8160 / 8180
43,0001,1436
400 V
43,0001,1437
600 V
43,0001,1438
1600 V