Fronius Selectiva 2100 Service Manual page 129

Table of Contents

Advertisement

Available languages

Available languages

(1)
(2)
(2)
(1)
(1)
(2)
(2)
The ten 4x9 TX20 tapping screws (2)
(3)
(2)
5
are used to fit the busbar, the contact
rails, the temperature sensor and the
capacitor module
[1.5 Nm]
Additionally secure the busbar with a
6
PT5x25 TX25 screw (3)
[1.5 Nm]
Screw fitting (1):
-
M6x16 hexagon bolt (5)
-
M6 brass washer (6)
-
M6 lock washer (7)
Fit the transformer leads and fuse with
5
four M6x16 hexagon bolts (1)
[10 Nm]
1
Fit the transformer connection lid
6
Fit the front panel (see the "Closing the
(5)
7
housing" section)
(6)
(7)
Device type Diodes
2100 / 2120 /
2140 / 2160 /
2180 / 2200 /
4060 / 4075 /
4090 / 4120 /
4140 / 4160
8040 / 8060 /
8075 / 8090
8120 / 8140 /
8160 / 8180
43,0001,1436
400 V
43,0001,1437
600 V
43,0001,1438
1600 V