Specifications
Environmental specifications
Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating
Nonoperating
* All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C
per hour (36°F per hour). The upper limit and rate of change might be limited by the type and number of
options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m
(10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
Server specifications
Specification
Height
Depth
Width
Minimum weight
Maximum weight
Power supply specifications
The server supports the ATX 300W Power Supply.
CAUTION: Check the system and power supply input ratings before powering up the server.
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
Minimum to be the higher (more moisture) of
-12°C (10.4°F) dew point or 8% relative
humidity
Maximum to be 24°C (75.2°F) dew point or
90% relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb
temperature
Tower model
36.76cm (14.47 in)
40.13cm (15.79 in)
17.50cm (6.89 in)
6.68 kg (14.73 lbs)
10.58 kg (23.32 lbs)
Specifications 71