External Analyzer
Specifications
Using the External Analyzer 4-12
Threshold Accuracy = + /- 50 mV.
•
Dynamic Range = + /- 10 V about threshold setting.
•
Minimum Input Swing = 600 mV pp.
•
Minimum Input Overdrive = 250 mV or 30% of threshold setting,
•
whichever is greater.
Absolute Maximum Input Voltage = + /- 40 V.
•
Probe Input Resistance = 100K ohms + /- 2%.
•
Probe Input Capacitance = approximately 8 pF.
•
Maximum + 5 Probe Current = 0.650 A.
•
+ 5 Probe Voltage Accuracy = + 5.0 + /- 5%.
•
External State Analyzer Specifications
Data Setup Time = 10 nS min.
•
Data Hold Time = 0 nS min.
•
Qualifier Setup Time = 20 nS min.
•
Qualifier Hold Time = 5 nS min.
•
Minimum Clock Width = 10 nS
•
Minimum Clock Period:
•
No Tagging Mode = 40 nS (25 Mhz clock).
—
Event Tagging Mode = 50 nS (20 MHz clock).
—
Time Tagging Mode = 60 nS (16 MHz clock).
—
Minimum Time from Slave Clock to Master Clock = 10 nS.
•
Minimum Time from Master Clock to Slave Clock = 50 nS.
•