U>tsq -t 5
U>tsto all
U>tsto 1 none
U>tp c
U>tsq
tif 1 p1 2
tif 2 p2 5
tif 3 p4 4
tif 4 p6 5
tif 5 never
tif 6 any 7
tif 7 any 8
tif 8 never
tsq -t 5
tsto 1 none
tsto 2 all
tsto 3 all
tsto 4 all
tsto 5 all
tsto 6 all
tsto 7 all
tsto 8 all
telif 1 never
telif 2 p3 3
telif 3 p5 1
telif 4 p5 1
telif 5 never
telif 6 never
telif 7 never
telif 8 never
Accessing Full Analyzer Capability 3-22
Specify Storage Qualifiers
Since each sequence term may have a storage qualifier, storage quali-
fier specification is part of the sequencer setup. Suppose, in the exam-
ple above, that you do not wish to store states while searching for
PROCESS_1 but that you wish to store all states after PROCESS_1 is
found. The commands below will do this. Remember, states which
cause sequencer branches are stored regardless of the trace storage
qualifier.
The command which follows will cause the trigger state to appear in
the center of the trace.
To view the resulting sequencer setup, enter the tsq command with no
options.