If Something Goes Wrong
My browser can't find any Internet site.
Test to see if your browser can find the Magnia SG20 intranet (http://192.168.1.1/).
If you can see this site, then check your cables and connectivity from the Internet port on
back of the Magnia SG20. Verify your Internet settings on the Administration Web site's
Internet page under the Network tab.
Contact your Internet Service Provider for further assistance.
My browser can't find the Magnia SG20 intranet.
If your browser cannot find the Magnia SG20 intranet, try browsing to "http://192.168.1.1/
" instead of "http://myserver/" or "http://myserver.loc" and instead of using the desktop
icon provided by the Magnia SG20 Setup CD. If this works, your server's name may have
been changed from "myserver." To see what your server's name is, browse to the Magnia
SG20 Administration Web site using "http://192.168.1.1:8282/." Click Advanced on the
Network tab's Local Network page. The initial factory setting for the Magnia SG20's name
is "myserver." If this has changed, all Magnia SG20 Setup CD desktop icons created
before the name change will need to be updated to reference the new name.
If you cannot browse to the intranet using "http://192.168.1.1/," then the Magnia SG20
may be turned off. It must be turned on and finished warming up before you can access
the intranet.
You should check to see if the Magnia SG20 is turned on.
Check your cables between the client machine and the Magnia SG20. Make sure the
client machine is connected to one of the seven local network ports. (Remember that the
eighth port is for expansion and cannot be connected directly to a client machine without
a cross-over cable.)
Reboot your client machine. If the client machine was powered on before the Magnia
SG20 was finished warming up, then your client machine might not be recognized and
assigned a valid IP address (Internet Protocol address) by the Magnia SG20. Rebooting
the client machine will fix this.

Other system problems

A client machine can no longer access anything.
The client machine may have lost its IP address. Reboot the client machine and try
again.
The Magnia SG20 Administration Web site is difficult to navigate due to scroll bars.
Check your screen area (a.k.a. screen resolution) and use of large fonts. For best
viewing, set your screen area to at least 800 by 600 pixels. Set it higher if you use large
fonts.