18. Hill Holder

A: REMOVAL
S405661A18
1. PHV (PRESSURE HOLD VALVE)
1) Remove air cleaner case. (Non-turbo model)
<Ref. to IN(SOHC)-7, REMOVAL, Air Cleaner
Case.>
2) Remove intercooler. (Turbo model) <Ref. to
IN(DOHC TURBO)-10, REMOVAL, Intercooler.>
3) Drain brake fluid from reservoir of master cylin-
der.
4) Remove adjusting nut and lock nut.
(1)
Adjusting nut
(2)
Lock nut
(3)
PHV
5) Remove cable clamp, and disconnect PHV
cable from PHV.
CAUTION:
Carefully protect boots and inner cable from
damage when disconnecting PHV cable.
(1)
PHV cable
(2)
Clamp
6) Disconnect brake pipes from PHV.
CAUTION:
¼ Pay attention not to drop brake fluid onto
body painting since it may dissolve paint.
¼ Pay attention not to damage hexagonal head
of flare nut by using pipe wrench without fail.
HILL HOLDER
S405661
S405661A1801
S4M0241C
S4M0242C
7) Detach PHV along with support from side
frame.
CAUTION:
Exercise utmost care to prevent foreign matter
from entering into PHV when removing it.
2. PHV CABLE
1) Remove air cleaner case. (Non-turbo model)
<Ref. to IN(SOHC)-7, REMOVAL, Air Cleaner
Case.>
2) Remove intercooler. (Turbo model) <Ref. to
IN(DOHC TURBO)-10, REMOVAL, Intercooler.>
3) Remove adjusting nut and lock nut.
(1)
Adjusting nut
(2)
Lock nut
(3)
PHV
BR-51
S4M0243
S405661A1802
S4M0241C
Brake

Advertisement