GROUNDING INSTRUCTIONS
1. All grounded, cord-connected tools:
In the event of a malfunction or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. This tool is equipped with an electric
cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and grounded in accordance with
all local codes and ordinances.
Do not modify the plug provided – if it will not fit the outlet, have the proper outlet installed
by a qualified electrician.
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock. The conductor with insulation having an outer surface that is green with or without
yellow stripes is the equipment-grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the equipment-grounding conductor to a
live terminal.
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3 pole receptacles
that accept the tool's plug.
Repair or replace damaged or worn cord immediately.
2. Grounded, cord-connected tools intended for use on a supply circuit having a nominal
rating less than 150 volts:
This tool is intended for use on a circuit that has an outlet that looks like the one
illustrated in Sketch A in Fig. 1. The tool has a grounding plug that looks like the plug
illustrated in Sketch A in Fig. 1. A temporary adapter, which looks like the adapter
illustrated in Sketch B and C, may be used to connect this plug to a 2-pole receptacle as
shown in Sketch B if a properly grounded outlet is not available. The temporary adapter
should be used only until a properly grounded outlet can be installed by a qualified
electrician. This adapter is not permitted in Canada. The green-colored rigid ear, lug
and the like, extending from the adapter, must be connected to a permanent ground such
Volts
120
240
6
10
12
16
Table A
Total length of cord in feet
25
50
50
100
Minimum gage for cord
18
16
18
16
16
16
14
12
100
150
200
300
16
14
14
12
14
12
Not Recommended
5