1c
Initial Wall Prep
Blocking (supplied by others) is required for proper support of
operator. Thickness is dependent upon Frame Return.
Material must comply with local codes.
A. For wood framing, screw blocking into wall studs.
B. Lag anchoring required for masonry walls.
Left hand door
illustrated.
Edge of Frame
or
C L
of Hinge
2a
Back Plate Mounting
i
ii
2b
For Concealed Wiring Only
A. Mark conduit holes using back plate as
template.
B. Remove back plate.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
"C" min
"B" max
i
Door Opening
Angle
85°
90°
95°
100°
105°
110°
A. Install (2) 1/4-20 x 1" screws
B. i) Install Back Plate assembly
over screws in Step 2A and
ii
ii) slide Back Plate toward
Latch edge of door.
C. Secure (2) screws.
C. Drill (2) Ø7/8" holes.
D. Install conduit in frame, if desired.
E. Reinstall back plate and secure (2) screws.
Page 5
ASSA ABLOY
See page 24
for removable
Frame
Return
4-7/8"
Dim "B"
Dim "C"
max
min
7"
21-3/4"
6-3/8"
21-1/8"
5-3/4"
20-1/2"
5-1/4"
20-0"
4-7/8"
19-5/8"
4-1/2"
19-1/4"
into holes drilled in Step 1B.
Leave 1/8" gap between
bottom of screw head and
frame.
80-9360-1003-020 (08-15)