Factory Pre-Wiring Of Connections; Basic Wiring Diagrams Using Factory Pre-Wiring Connections - Norton 6000 Series Installation And Instruction Manual

Power operator
Table of Contents

Advertisement

Factory Pre-Wiring of Connections

Signal
24VDC
(Dry)
Power
Contacts
Outputs
Basic Wiring Diagrams Using Factory Pre-Wired Connection
Standard Function with
Switches
Doors are normally
Ÿ
closed.
Activating either switch
Ÿ
will open both doors.
Door will close after hold
open time delay has
expired.
Fail Secure Electric Strike
24VDC Wiring
Doors are normally closed and
Ÿ
latched.
Activating switch will unlock
Ÿ
electric strike and door will
automatically open. Door will
close after hold open time delay
has expired.
The door will remain locked
Ÿ
during power failure.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
120VAC
Power
Inputs
Line Neutral
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
24VDC
Electric Strike
(Fail Secure)
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Page 14
ASSA ABLOY
Aux1
GND
Pres Det
GND
Aux2
GND
Door Toggle
GND
Aux1
Aux3
GND
Aux2
No Conn
Blow Open
+
-
80-9360-1003-020 (08-15)