Norton 6000 Series Installation And Instruction Manual page 22

Power operator
Table of Contents

Advertisement

433MHz Receiver User's Guide
ON
ON
1
2
1
2
In Toggle Setting (1-ON), the
Hold Time is inactive. Either
setting for #2 dip switch will
have the same result.
#1
Description
OFF
Pulse Relay
ON
Toggle Relay
#2
Description
OFF
0.5s Hold Time
ON
10s Hold Time
R1
Hand-Held Configuration
1. Set dip switches to the receiver to the desired activation cycle (dip switch 1 - Toggle or Pulse and dip switch 2 - 0.5s or 10s
hold.
2. Press either Learn w/ Delay Button or Learn w/o Delay Button on the receiver depending on the activation requirements (if
delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). Red LED on receiver will flash. After
learn cycle is complete, adjust potentiometer to desired delay time (0 - 30 sec).
3. Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from
transmitter).
NOTE: Repeat Steps 2 - 3 to program additional transmitters.
4. To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED
illuminates on the receiver. This indicates that the relay has been activated.
R2
Push Plate Configuration
1. Before beginning, it is easiest to have already prepared the installation of the push plate.
2. Connect the wires from the transmitter to the NO and COM contacts of the push plate's switch.
3. Follow Steps 1 - 4 (Hand-Held Configuration); depress the push plate to activate the transmitter.
4. Attach the transmitter to the inside of the electrical box and complete the installation.
R3
Removing Transmitter Code(s)
Single Transmitter Code:
Press both Delay and No Delay Buttons simultaneously until Red LED flashes once (approximately 1 second).
Ÿ
Press transmitter button twice within 10 seconds and the transmitter code will be deleted.
Ÿ
All Transmitter Codes:
Press and hold both Delay and No Delay Buttons simultaneously until Blue LED illuminates then release (approximately 10
Ÿ
seconds).
R4
Troubleshooting
Problem: The LED on my receiver is just flickering and I'm unable to program and/or it won't work.
Solution: You have a push plate stuck or faulty transmitter. Disconnect each push plate until the LED goes out. If LED
Problem: Receiver intermittently doesn't receive the transmitter(s) signal.
Solution: You may extend the receiver antenna wire only in multiples of 6-3/4" (171), i.e. 6.75 x 4 = 27" (686) of
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ON
1
2
0.5 second
Pulse Setting
Function
Press the transmitter once and the relay will be active
momentarily.
Press the transmitter once and the relay output is
active indefinitely, press it again and the relay will de-
energize indefinitely.
Function
Relay will remain active 0.5 sec after loss of activation.
Relay will remain active 10 sec after loss of activation.
does not go out, remove each transmitter battery until it does. Replace the appropriate transmitter.
extended antenna wire.
ON
1
2
10 second
Pulse Setting
Page 22
Antenna Wire
Terminal
Strip
DIP Switch
Learn w/
Delay Button
Always stop pedestrian traffic through the
Ÿ
doorway when performing tests that may
result in unexpected reactions by the door.
Ÿ
Ensure compliance with all applicable safety
standards upon completion of installation.
80-9360-1003-020 (08-15)
ASSA ABLOY
Blue LED
Red LED
Learn
w/o Delay
Button
Delay
Potentiometer
(Time Adjustment)

Hide quick links:

Advertisement

Table of Contents
loading