Controller Interface Description

Screen Display
Mount:
Push:
Obst Delay:
Hold Open:
Open Speed:
Close Speed:
Slow Speed:
Hold Speed:
Start Delay:
Vestibule:
Latch Rtrct:
Alarm Delay:
A2
Rly2:
Cycles:
Days:
Open Time
Close Time
Errors
Home
Save Values
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Adjustments
Push or Pull
OFF or PushNGo
0 - 5 sec in 1 sec increments
0 - 30 sec in 1 sec increments
0 - 100% in 1% increments
0 - 100% in 1% increments
0 - 100% in 1% increments
0 - 100% in 1% increments
0 - 10 sec in 1 sec increments
OFF, 5 - 30 in 5 sec
increments
OFF, 3 - 45 in 3 sec
increments
OFF, 30 sec, 60 sec
Standard, Presence Off,
Presence On
Alarm, Activation, On
Opened, On Closed
not adjustable
not adjustable
not adjustable
not adjustable
not adjustable
see Setting Open Position
Save Values or Saved
Default
Description
Pull
Side of opening operator is mounted on
Turn on or off Push N Go feature.If On, a slight push or pull of
Off
the door starts it automatically opening.
Obstruction Delay: the amount of time the operator will push
against an obstruction before closing if during an opening cycle
3s
or reopening and trying to close again if during a closing cycle.
6s
Amount of time door will stay in full open position.
100
How fast the door opens to full open position.
How fast the motor returns to the home position. As Latch and
Sweep on the closer are adjusted, adjustments may be needed
for Close Speed to assure closer is not trying to backdrive the
60
motor.
Speed up or slow down door during last few degrees of
55
opening.
Increase or decrease hold open force (when in "ON" position
only, not "H/O") to compensate for spring force, wind
55
conditions, etc
Time before operator begins to open door. This is to allow
accessories time to function and not hinder the opening of the
0s
door.
Off
Amount of delay for opening 2nd vestibule door
Off
Amount of time power is supplied to a latch retraction device.
Off
Used only for alarm accessories.
A2 input can be used for Alarm Delay or Input for door mounted
presence detector: Presence Off - door will not reactivate;
Presence On - door will reopen if presence detected during
Standard
closing cycle.
How Relay 2 is used: Alarm - used with above Alarm Delay;
Activation - acts as an additional NO / NC contact; On Opened -
relay trips (closed contacts) when door is in opened position;
On Closed - relay trips (closed contacts) when door reaches
Alarm
the fully closed position.
-
Number of electrical cycles on the operator.
Number of full days electricity have been supplied to the
-
operator.
Time it took for previous opening cycle to go from Home to fully
-
open position.
Time it took for previous closing cycle to go from fully open
-
position to Home.
Error code seen by controller. See below for Troubleshooting
-
codes.
Used to set the Home position and the Fully Open positions of
-
the operator.
-
Used to permanently add adjustments to controller's memory.
Page 13