General Electrical Information; Safety Instructions; Controller Error Codes - Norton 6000 Series Installation And Instruction Manual

Power operator
Table of Contents

Advertisement

General Electrical Information

Circuit
Breaker
Power
On / Off
Switch
Power
Input and
Basic Aux
Connection
IMPORTANT SAFETY INSTRUCTIONS - WARNING:
1) READ AND FOLLOW ALL INSTRUCTIONS.
2) Never let children operate or play with door
controls. Keep the remote control (where provided)
away from children.
3) Personnel should keep away from a moving door in
motion.
4) Test the door's safety features at least once a
month. After adjusting either the force or the limit
of travel, retest the door operator's safety features.

Controller Error Codes

Error Code
Short Circuit
Temperature Trip
Over Voltage
Under Voltage
Aux 1 Stuck
Aux 2 Stuck
Aux 3 Stuck
Comm Error
Presense Detect
Drive Disabled
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Powered
Output
Contacts
Auxiliary
Dry
Contacts
A short was sensed on the motor outputs
Power module reached 200°F or greater (too much load in too hot ambient
condition)
Line Voltage has reached 145VAC or greater
Line Voltage has dropped below 80VAC
Activation device connected to Aux 1 is sending constant signal
Activation device connected to Aux 2 is sending constant signal
Activation device connected to Aux 3 is sending constant signal
No communication between top and bottom controller boards. Boards not
functioning properly
Device connected to Presence Detect and was activated
3-position switch on end cap closest to latch is in "OFF" position
A. Power inputs at Power Input Connection and
Power Output Contacts must be made with
copper wire only.
B. Maximum wire size:
12 AWG at Power Input connection
14 AWG at all other terminals.
C. Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%).
D. Maximum current draw from auxiliary devices
is 1.3 amps.
E. All wiring and connections use standard
wiring practice conforming with local wiring
codes.
F. Labeled fire or smoke barrier door
assemblies require the 120VAC 60Hz
power input be supplied through normally
closed alarm contacts of the alarm
system / alarm panel.
To reduce the risk of severe injury or death
Failure to adjust the operator properly may
cause severe injury or death.
5) KEEP DOOR PROPERLY OPERATING. See
Door Manufacturer's Owner's Manual. An
improperly operating door could cause severe
injury or death. Have a trained door systems
technician make repairs.
6) SAVE THESE INSTRUCTIONS.