Incoming Power Connection

Incoming Power
Surface
Mounted
Conduit
Shown
A. Pull wire thru Incoming Power conduit.
B. Strip insulation back 3/8" on Hot and
Common Incoming Power wires.
C. Insert stripped end of wire into terminal.
14

Controller Interface

A. To power unit, flip switch on end cap furthest from the hinge
from "OFF" to "ON" position.
B. To scroll thru menu items, push up or down on joystick.
C. To change setting of a menu item, when cursor is on that
item, push joystick right to increase or left to decrease value.
D. To permanently accept changes to settings, scroll down to
"Save Values" and press in on the joystick. NOTE: If power is
turned off to the unit before "Save Values" has been accepted
to "Saved", any changes made to that point will be lost.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Low voltage /
Control Wiring
Ground Screw
(Green)
Incoming Power
Insert
Wire
Concealed
Conduit
Shown
Low voltage /
Control Wiring
D. Secure wire into terminal by turning screw
using a small flat blade screw driver.
E. Attach ground wire to green ground screw.
Joystick
See Page 13 for Controller
Page 10
ASSA ABLOY
Secure
120VAC
Signal
24VDC
Power
Screw
(Dry)
Power
Inputs
Contacts
Outputs
Line Neutral
LCD
Screen
Adjustment Options.
80-9360-1003-020 (08-15)