Door Prep

Hollow Metal Door Frame Reinforcing
Frame
Material
Recommended
12 Ga.
.1046
(2.66)
14 Ga.
.0747
(1.90)
16 Ga.
.0598
(1.52)
18 Ga.
.0478
(1.21)
Fasteners for Frame:
1/4-20 Machine screws for hollow
metal and aluminum.
No. 14x2-3/4 " (70mm) long sheet
metal screws for wood.

Technical Data

Input power:
Power consumption:
Circuit breaker:
Power supply:
Door width:
Door weight:
Door opening angle: up to 110° with reveal up to 3" (7.6 cm) max
Hold open time:
Rate of operation shall not exceed 300 cycles of opening and closing per hour.

Standards

ETL Certified; conforms to ANSI/UL standard 325 for
automatic closing doors and UL10C
Test for Door Assemblies
ANSI A156.19:
These products are designed to conform to this specification
"for power assist and low energy power operated doors."
These products are designed to exceed all the requirements
for the "Low Energy Power Operated Door."
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Reinforcing
Min. Required
12 Ga.
18 Ga.
.1046
.0478
(2.66)
(1.21)
10 Ga.
12 Ga.
.1343
.1046
(3.41)
(2.66)
10 Ga.
12 Ga.
.1343
.1046
(3.41)
(2.66)
8 Ga.
10 Ga.
.1644
.1343
(4.18)
(3.41)
120VAC, 60Hz
.9 amps
3 amps
24 V DC, max. 2.2 Amp.
28 - 48" (71-122 cm)
100-250 lb. (45-113 kg)
0-30 seconds (A.D.A. 5 seconds min.)
Indefinite for optional Extended Hold Open
Positive Pressure Fire
.
Templating is based on 1/8" gap between door and frame.
Notes:
• All dimensions are given in inches.
• Thickness recommended for reinforcements in hollow metal doors
and frames is charted at the left of this page.
• Do not scale drawing.
• This template information based upon use of 5" maximum width butt
hinges.
• Maximum frame reveal is 4-3/4" for 6060 units and 4-13/16" up to 7-
3/8" maximum for 6070 units.
• Before beginning the installation, verify that the door frame is properly
reinforced and is well anchored in the wall.
• Unreinforced hollow metal frames and aluminum frames should be
prepared and fitted with 1/4-20 blind rivet nuts, furnished by others.
• Concealed electrical conduit and concealed switch or sensor wires
should be pulled to the frame before proceeding.
Notes: Permanent wiring is to be employed as
Maximum wire size is:
Americans with Disabilities Act (A.D.A.)
These door operators can be installed and adjusted to
conform with A.D.A. regulations.
ANSI A117.1:
These door controls permit door assemblies to
conform to the requirements of this specification "for
buildings and facilities - providing accessibility and
usability for physically handicapper people."
Page 3
Frame
Door
1/8"
(3)
required by local codes.
Activation devices: push plates, access
control, mats, touchless wall switches, etc.
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
mounted on inside of end cap.
14AWG at all other terminals.
80-9360-1003-020 (08-15)