Vestibule Function Wiring - Norton 6000 Series Installation And Instruction Manual

Power operator
Table of Contents

Advertisement

Vestibule Function Wiring

Using Factory Pre-Wiring
Inside Switch
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Vestibule Function Wiring
Ÿ
Doors are normally closed and latched.
Activating outside door switch will open the outside door.
Ÿ
After the vestibule time delay has elapsed, a signal will be
sent to the inside door which will open. Activating the inside
door switch will open the inside door. After the vestibule time
delay has elapsed, a signal will be sent to the outside door
which will open. Both doors will close when the hold open
time delay has elapsed.
Activating the optional inside door switch located within the
Ÿ
corridor will open the inside door only. This door will re-close
after the hold open delay has elapsed.
Activating the optional outside door switch located within the
Ÿ
corridor will open the outside door only. This door will re-
close after the hold open delay has elapsed.
OUTSIDE
DOOR
Outside Switch
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
INSIDE DOOR
Optional Inside
Corridor Switch
Aux1
GND
Pres Det
GND
Aux2
GND
Door Toggle
GND
Aux1
Aux3
GND
Aux2
No Conn
Optional Outside
Blow Open
Corridor Switch
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Page 20
ASSA ABLOY
Aux1
GND
Pres Det
GND
Aux2
GND
Door Toggle
GND
Aux1
Aux3
GND
Aux2
No Conn
Blow Open
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
80-9360-1003-020 (08-15)