1.5 Fieldbus port expansions cards

pCO5plus +0300020EN rel. 1.2 - 07.11.2013
PCO10000F0
LonWorks® interface
(tech. leafl et code
card
+050004045)
PCOS00KXB0
Konnex interface
card
(tech. leafl et code
+050000770)
PCOS00HBB0
CAN-bus serial card Allows connecting to CANbus networks, specifi cally to e-drofan fan coil
(tech. leafl et code
+050000162)
Code
Description
PCO100FD10
RS485 serial card
(tech. leafl et code
+050003270)
PCO100TLN0
tLAN and PST
(tech. leafl et Code
serial card
+050003270)
PCO100MPB0
MP-BUS card
(tech. leafl et code
+050003270)
PCOS00KXF0
Konnex interface
(tech. leafl et code
card
+050000770)
PCOS00HBF0
CAN-bus serial
(tech. leafl et code
card
+050000162)
Allows connecting to a LonWorks® TP/FT 10 network. The program resides in the fl ash
memory located in the socket, and can be programmed directly via the LonWorks®
network using network installation and maintenance tools such as LonMaker™.
Information on how to program the card is available in the relative manual, code
+030221960.
Allows connecting to a network set up according to the Konnex® standard. Two
versions available: for BMS port and Fieldbus port.
controllers, thanks to the capacities of the e-dronic system. This simplifi es plant
operation, optimizing comfort, enhancing synergies between controllers and
reducing operating costs. Two versions available: for BMS port and for Fieldbus
port.
Notes
Allows connecting to an RS485 network (through an electrically isolated interface).
The controller consequently acts as a MASTER (i.e. supervisor), therefore other con-
trollers or devices can be connected as SLAVES. Up to 64 devices can be connected.
Allows connecting to a tLAN network through two separate connectors. The fi rst
is used to connect the controller to a tLAN network. Using this connection and a
suitably confi gured application in TLAN MASTER mode, the controller can interact
with the I/O expansion cards (tLAN version - PCOE00TLN0) or with other controllers
provided with a tLAN connection, confi gured in tLAN SLAVE mode.
Up to 5 devices can be connected. The second connector is used to connect to a
PST terminal. Both connections require using a shielded cable having a maximum
length of 10 m.
Attention: Do not use both connectors at the same time
Allows connecting to an MP-Bus network consisting of devices (sensors, actuators)
set up according to the Belimo standard. Up to 8 actuators can be connected at
the same time, at a maximum distance of 30 m. See the specifi c documentation
provided by Belimo (www.belimo.ch).
See description of PCOS00KXB0 serial card (previous paragraph).
See description of CAN-bus PCOS00HBB0 serial card (previous paragraph).