Mitsubishi Electric FX5 User Manual page 194

Melsec iq-f series
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

■Control data
Device Item
(s)
Result of executed
protocols
(s)+1
Resulting number of
executed protocols
(s)+2
Execution protocol
number 1
(s)+3
Execution protocol
number 2
(s)+4
Execution protocol
number 3
(s)+5
Execution protocol
number 4
(s)+6
Execution protocol
number 5
(s)+7
Execution protocol
number 6
(s)+8
Execution protocol
number 7
(s)+9
Execution protocol
number 8
(s)+10
Verification match
Receive packet
number 1
(s)+11
Verification match
Receive packet
number 2
(s)+12
Verification match
Receive packet
number 3
(s)+13
Verification match
Receive packet
number 4
(s)+14
Verification match
Receive packet
number 5
(s)+15
Verification match
Receive packet
number 6
(s)+16
Verification match
Receive packet
number 7
(s)+17
Verification match
Receive packet
number 8
*1 User: Data to be set by users before the execution of the S(P).CPRTCL instruction.
System: Data to which the CPU module sets the execution result of the S(P).CPRTCL instruction.
6 PREDEFINED PROTOCOL SUPPORT FUNCTION
192
6.8 Programming
Description
The result of executed S(P).CPRTCL instruction is stored. When two or more protocols are
executed, the execution result of the protocol executed last is stored.
• 0: Normal completion
• Other than 0: Error completion (error code)
The number of protocols executed by the S(P).CPRTCL instruction is stored. The execution of the
protocol where an error has occurred is also counted in the number of executions. If the setting of
setting data or control data contains an error, "0" is stored.
Specify the number of the protocol to be executed first.
Specify the number of the protocol to be executed second.
Specify the number of the protocol to be executed third.
Specify the number of the protocol to be executed fourth.
Specify the number of the protocol to be executed fifth.
Specify the number of the protocol to be executed sixth.
Specify the number of the protocol to be executed seventh.
Specify the number of the protocol to be executed eighth.
If receiving is included in the communication type of the protocol that has been executed first, the
receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the first protocol, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed second,
the receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the second protocol, "0" is
stored. If the number of protocols executed is less than 2, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed third, the
receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the third protocol, "0" is stored. If
the number of protocols executed is
less than 3, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed fourth,
the receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the fourth protocol, "0" is stored.
If the number of protocols executed is
less than 4, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed fifth, the
receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the fifth protocol, "0" is stored. If
the number of protocols executed is less than 5, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed sixth, the
receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the sixth protocol, "0" is stored.
If the number of protocols executed is
less than 6, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed seventh,
the receive packet number successful in verification match is stored.
If the communication type is "receive only", "0" is stored. If an error occurs during execution of the
seventh protocol, "0" is stored. If the number of protocols executed is less than 7, "0" is stored.
If receiving is included in the communication type of the protocol that has been executed eighth,
the receive packet number successful in verification match is stored. If the communication type is
"receive only", "0" is stored. If an error occurs during execution of the eighth protocol, "0" is stored.
If the number of protocols executed is less than 8, "0" is stored.
*1
Setting
Set by
range
System
0, 1 to 8
System
1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 64
User
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System
0, 1 to 16
System