Operation error
Operation errors pertaining to the instruction are as follows.
Operation Error Flag
SM0
SM1
ON
ON
ON
ON
Program example
Switches the operation speed (HED) of the inverter (Station No.3) to speed 1 (40 Hz)/speed 2 (20 Hz) with 60 Hz as the
initial value on startup.
Writing contents: D10 = operation speed (initial value: 60 Hz, speed 1: 40 Hz, speed 2: 20 Hz)
RUN monitor
SM400
Switch command
(Speed 1)
M10
Switch command
(Speed 2)
M20
4 INVERTER COMMUNICATION
106
4.8 Programming
Operation Error
Codes
SM56
SM8067
SD0
1810
2820
3405
3600
MOVP
M20
MOVP
M10
MOVP
(s1)
(s2)
IVDR
K3
HED
Description
SD8067
When specified channel is used with another instruction.
When specified device exceeds the device range.
When the value specified for (s1) is other than K0 to 31.
When the value specified for (n) is other than K1 to 4.
When specified channel is not setting parameter.
K6000
D10
Initial value at startup: 60 Hz
K4000
D10
Operation speed: 40 Hz
K2000
D10
Operation speed: 20 Hz
(s3)
(n)
(d)
D10 → Set frequency write (RAM)
D10
K1
M200
Head bit device number of instruction
execution status output
Communication channel: 1 to 4
Read value storage destination
Inverter instruction codes
Inverter station number: 0 to 31