Lennox iComfort E30 Installation And Setup Manual page 38

Smart thermostat
Hide thumbs Also See for iComfort E30:
Table of Contents

Advertisement

Initial notification of critical alerts will pop up on the home screen and will be listed under notification menu. Minor and moderate alerts are found only under the notification menu.
Applicable
Alert
Priority
System
Code
Condition
Component(s)
65545
Minor
E30 System
Table 16. Alert Codes and Troubleshooting
Actual Displayed Alert
Component or System Operational State and Troubleshooting Tip
Text
This indicates the system is not running cooling mode in optimized efficiency. There may
be a component or components that will require attention.
NOTE:
Currently this is a minor alert and will not generate an email notification to the
dealer or homeowner. Parameter settings for this feature are hidden for the soft-
Cooling Prognostics Alert
ware version 3.2 release. The information will be used for data collection only and
(capacity alert)
sent to the Lennox server.
This algorithm will determine whether the unit will run out of capacity during the hottest
time of summer. It will look back everyday a minimum of three days to see if there is a
pattern and compare it to the hottest day on record for that zip code before triggering an
alert. It must see a pattern before it will trigger the alert.
38
How to clear alert code
The system will continue to count
the number occurrences within a 24
hours period where system demand
is not achieved. Will clear once
cooling demand is achieved.

Advertisement