Table 7. Smart Hub Parameters
Parameter
Description
Heating - Dual Fuel - 3 Stages (2 compressor / 1 backup)
H/C
Stages
Locked =
Disabled
3rd stage
ON
H/C
Stages
Locked =
Enabled
3rd stage
ON
POINTS:
SP -3.5
SP -3.0
SP -2.5
Heating - Dual Fuel - 4 Stage (2 compressor / 2 backup)
H/C
Stages
Locked =
Disabled
3rd stage
ON
Stg3 Differential
4th stage
ON
Stg4 Differential
H/C
Stages
Locked =
Enabled
3rd stage
ON
Stg3 Differential
4th stage
Stg4 Diff.
ON
P
O
N I
T
: S
SP -3.5
SP -3.0
SP -2.5
Default Group ID is 1. Valid range is 0 to 9.
Multiple Smart Hubs in a home can be assigned to a group (up to nine
groups with up to eight Smart Hubs in each group). All Smart Hubs in a
Group ID
group can communicate with other Smart Hubs in the same group over
the home Wi-Fi network.
If a Smart Hub is set to Group ID 0, there will be no connectivity with
another Smart Hub.
Range is -10.0 to 10.0%. Default is 0.0%.
Humidity Reading
If it is determine that the actual humidity percentage being detected at
Calibration
the thermostat is off based on independent readings using other humidi-
ty reading devices, the display can be adjusted using this setting.
1st stage
ON
2nd stage
ON
Stg2 Differential
Stg3 Differential
1st stage
ON
2nd stage
ON
Stg2 Differential
Stg3 Differential
SP -2.0
SP -1.5
SP -1.0
SP -0.5
1st stage
ON
2nd stage
ON
Stg2 Differential
1st stage
ON
2nd stage
ON
Stg2 Differential
SP -2.0
S
P
1 -
5 .
S
P
1 -
0 .
S
P
0 -
5 .
Parameter
Lock In 2nd Stage
HP by Outdoor
Temp
(Lennox Two-Stage
Heat Pumps Only)
Stg1 Differential
2nd
stage
Max Heat Setpoint
OFF
Max Humidification
Setpoint
Stg1 Differential
Min Cool Setpoint
SP
SP
Min
Dehumidification
Setpoint
Outdoor
Temperature
Stg1 Differential
Reading
2nd
Calibration
stage
OFF
Reset Smart Hub
4th
stage
Severe Weather Protection
OFF
(high and low temperature notification)
Options are enabled or disabled. Default is disabled. When enabled either the heat or freezing
Stg1 Differential
alert temperature setting will automatically generate a email notification to the homeowner that the
applicable condition exist and homeowner interaction is required.
NOTE:
Notification is dependent on the thermostat having a active Wi-Fi connection and the user
account has been setup and includes a valid email address.
SP
SP
Heat Alert
Temperature
Freezing Alert
Temperature
Single Setpoint Mode (SSP)
On the user screens this is referred to as Perfect Temp (Temperature). Options are enabled or
disabled. Default is disabled. The Single Set Point (SSP) algorithm allows the user the set only
one temperature set point value rather than one value for heating and a different value for cooling.
When zoning is present, the following SSP settings are not available. When enabled the following
parameters are automatically configured for optimal settings.
25
Table 7. Smart Hub Parameters
Description
This accessory allows the unit to lock in 2nd stage HP heating when the
outdoor temperature goes below the jumper pin setting.
Options are off, 40°F, 45°F, 50°F and 55°F (4°C, 7°C, 10°C and 3°C).
Default is off.
The highest temperature setting that the heat set point can be set on the
thermostat. Default is 90.0F (32.33°C). Range is 60.0 to 90.0°F (15.56 to
32.22°C). Adjustable in increments of 1°F (0.56°C).
Maximum allowed set point for humidification.
Range is 15 to 45%. Default is 45%. Adjustments are in increments of
1%.
The lowest temperature setting that the cool set point can be set on the
thermostat. Range is Range is 60.0 to 90.0°F (15.56 to 32.22°C). De-
fault is 60°F (15.56°C). Adjustments are in increments of 1°F (0.56°C).
Adjustable minimum dehumidification setting.
Range is 40 to 60%. Default is 40%. Adjustments are in increments of
1%.
Range is -10 to 10°F (-5.56 to 5.56°C). Default is 0°F (0.0°C). Adjust-
ments are in increments of 1°F. (0.56°C) This will allow for adjustment
to the outdoor temperature display when the display temperature is off.
Outdoor sensor is required.
Reset Smart Hub (erases Smart Hub settings and restarts installer
setup).
This will notified the homeowner when the indoor temperature reaches
the setting defined for this parameter. Range is 80°F to 100°F (26.67 to
37.78°C) with a factory default of 90°F (32.22°C). Increments adjusted
by 1.0°F (0.56°C).
This will notified the homeowner when the indoor temperature reaches
the setting defined for this parameter. Range is 30°F to 50°F (-1.11 to
10.0°C) with a factory default of 40°F 4.4°C). Increments adjusted by
1.0°F (0.56°C).