Table 7. Smart Hub Parameters
Parameter
Description
Number of stages in thermostat is dependent on equipment that is
installed.
Stage
Differentials
NOTE:
Variable capacity systems will stage electric heat but not on dif-
ferentials. It will use the thermostat PI logic to stage the electric
(1 through 6)
heat. If the system has a variable capacity furnace or zoning all
stage differentials will be ignored.
Range is -5.0 to 5.0°F (-2.78 to -2.78°C). Default is 0.0°F (-0.0°C).
If it is determine that the actual temperature being detected at the
Temp Reading
thermostat is off based on independent readings using other ambient
Calibration
temperature reading devices, the display can be adjusted using this
setting.
Options are Normal and Comfort. Default is Normal. The Feels-Like fea-
ture factors in the outdoor temperature and indoor humidity for a more
accurate control of the temperature in the home. Either an outdoor tem-
perature sensor is used or Internet Weather is enabled for this feature to
operate. Modifying this setting here will also change the feature status
on the user settings screen.
Temperature
Control Mode
Normal - This setting cools or heats the home to the desired
temperature setting (feels-like) is OFF.
Comfort - This setting cools or heats the home to the desired
temperature setting (Feels Like) is ON. When set to ON, other
parameters are modified to optimal settings for this feature. Those
setting changes will be listed on-screen when Comfort is enabled.
Wall Insulation
Options are poor, average and good. Default is average.
Table 8. Air Handler Parameters
Parameter
Description
Provides information concerning unit code, language support, equipment
type name, unit model number, unit serial number, unit nominal capacity,
number of heating states, heating capacity by stage, indoor blower CFM
range, control software revision, control model number, control serial
number, control hardware revision, discharge air temp sensor, outdoor
About
air temp sensor, protocol revision number, device product level, factory
installed transformer, 24VAC average power consumption, 24VAC peak
power consumption, line voltage average power consumption, line volt-
age peak power consumption, compatible devices list, applicable code
memory size, and micro-controller part number..
Any installer modifications under the air handler tab will be reset back to
Reset Air Handler
the factory defaults if the reset air handler option is used.

Air Handler

Table 9. Furnace Parameters
Parameter
Description
This screen provides information on unit code, language supported,
equipment type name, unit model number, unit serial number, unit
nominal capacity, number of heating stages, heating capacity by stage,
indoor blower CFM range, control software revision, control model
number, control serial number, control hardware revision, discharge air
About
temp sensor, outdoor air temp sensor, protocol revision number, device
product level, factory installed transformer, 24VAC average power con-
sumption, 24VAC peak power consumption, line voltage average power
consumption, line voltage peak power consumption, compatible devices
list, application code memory size and micro-controller part number.
Any installer modifications under the furnace tab will be reset back to
Reset Furnace
the factory defaults if the reset furnace option is used.

Thermostat (HD Display)

Table 10. Thermostat (HD Display) Parameters
Parameter
Description
This screen provides information concerning model number, serial
About
number, hardware revision, software revision, language support and
equipment type name.
Auto Brightness
Options are on and off. Default is off.
The brightness range is 0 - 100. Default 80. Touch either the + or - but-
Brightness Value
ton to increase or decrease the setting.
Options are on and off. Default is off. Air Quality is displayed under the
Display Air
weather display. Touch the Weather icon on the home page to see the
Quality
current air quality.
Display Indoor
Options are on and off. Default is off.
Humidity
Display Outdoor
Options are on and off. Default is off.
Weather
Outdoor
Options are off, Internet (AccuWeather) or sensor. Default is Internet
Temperature
(AccuWeather).
Source
Options are ON and OFF. Default is OFF. Is used to wake-up the display
Proximity Control
from screen saver mode when motion near the HD Display is detect-
ed.
Reset thermostat
Resets the thermostat settings to factory default.
Screen Locked
Options are unlocked, partially locked and locked. Default is unlocked.
Screen Saver
Options are off, weather, power save and logo. Default is off.