Instl: Rgstltn Rst
Displays a number that indicates the registration result.
0: Succeeded
2: Registration in progress
3: Proxy error (proxy enabled)
5816 207
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Registration executing
Instl: Error Code
5816 208
Displays a number that describes the error code that was issued when either SP5816-204
or SP5816-207 was executed.
Cause
Illegal Modem
Parameter
Operation Error,
Incorrect Setting
Code
Meaning
-11001
Chat parameter error
-11002
Chat execution error
-11003
Unexpected error
Inquiry, registration attempted without
-12002
acquiring device status.
Attempted registration without execution of
-12003
an inquiry and no previous registration.
Attempted setting with illegal entries for
-12004
certification and ID2.