4. Replacement and Adjustment
4
2. Disconnect two connectors and release four clamps.
3. Take aside the harnesses on the paper exit unit [A].
4. Remove four screws on the paper exit unit.
5. Remove the gear [A] (hook) and bushing [B].
• This gear is engaged with other drive gears through the timing belt. Check if the timing belt is
correctly installed after installing the paper exit unit.
6. Paper exit unit [C]

Fusing Exit Sensor

1. Upper cover (
2. Paper exit unit (
62
p.30)
p.61)