Ricoh Kr-P2 Field Service Manual page 131

Hide thumbs Also See for Kr-P2:
Table of Contents

Advertisement

Thermistor Adjust
2910
If this is "Yes", the machine automatically adjusts the charge roller voltage and transfer
current in response to the temperature within the machine.
2911
PreRotate Time
Curl Reduction
2911 2
Specifies the pre-rotation time at power-on or recovery from the energy saver mode.
LowTemp PreRotate
2911 3
Specifies the pre-rotation time at power-on or recovery from the energy saver mode in
low temperature environment (less than -15°C).
Waste Toner Count
2980
Displays the waste toner counter in the engine board.
SP3-xxx: Process
Ab Chrg Thermist
Displays the result of the charge thermister check (temperature) monitored by the loop
back connector.
3910
0: Normal
1: Low temperature limit
2: High temperature limit
3920
Density Adjust
Density (1)
3920 1
Adjusts the image density level in 120.8 mm/sec. line speed.
+3: Darkest/ -6: Lightest
Density (2)
3920 2
Adjusts the image density level in 161.4 mm/sec. line speed.
+3: Darkest/ -6: Lightest
0: Yes, 1: No DFU
[0 to 40 / 20 / 5 sec/step]
[0 to 40 / 20 / 5 sec/step]
[0 to 2 / 0 / 1 /step]
[-6 to 3 / 0 / 1 /step]
[-6 to 3 / 0 / 1 /step]
SP Tables
3
33

Advertisement

Table of Contents
loading

Table of Contents