0x0387: Event: at Aug 5 16:16:14 2009; from:(0x86,0,0);
sensor:(0x01,12); event:0x1(deasserted): "Upper Non-
Critical", Threshold: 0x28, Reading: 0x27
You can use the threshold command (see
check the threshold values of these sensors.
# clia threshold 86 12
Pigeon Point Shelf Manager Command Line Interpreter
86: LUN: 0, Sensor # 12 ("TEMP1")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x28 Processed data:
40.000000 degrees C
Upper Critical Threshold, Raw Data: 0x32 Processed data:
50.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x3c Processed
data: 60.000000 degrees C
The first two SEL lines below indicate a problem (last hex number is not 0x88) for the
IPMB link (sensor F1) on slot 9 and 10. The problem has cleared quickly because the last
two lines show last hex number is 0x88.
0x0219: Event: at Aug 6 10:39:54 2009; from:(0x88,0,0);
sensor:(0xf1,1); event:0x6f(asserted): 0xA2 0x00 0x89
0x021A: Event: at Aug 6 10:39:55 2009; from:(0x8c,0,0);
sensor:(0xf1,1); event:0x6f(asserted): 0xA2 0x00 0x8F
0x021C: Event: at Aug 6 10:39:55 2009; from:(0x88,0,0);
sensor:(0xf1,1); event:0x6f(asserted): 0xA3 0x00 0x88
0x021E: Event: at Aug 6 10:39:56 2009; from:(0x88,0,0);
sensor:(0xf1,1); event:0x6f(asserted): 0xA3 0x00 0x88
clia sensor [-v] [<IPMB-address> [<sensor-name> |
[<lun>:]<sensor-number>]]
This command displays information about specific sensor(s). The target sensor is selected
by its IPM controller's IPMB address and by sensor number or by sensor name. If neither
sensor name nor sensor number is specified, information about all sensors on the
specified IPM controller is displayed. If no parameters are specified, information about all
known sensors is displayed.
The following information is shown for each sensor in standard mode (non verbose mode):
IPMB address of the owning IPM controller
Sensor number, sensor name (device ID string from the Sensor Data Records (SDRs))
and the LUN by which the sensor can be accessed
The sensor type and event/reading type code
The Entity ID, Entity Instance of the related entity (the FRU device ID if the sensor is
associated with a FRU)
Example for slot 11 and sensor 13: