shmstatus

shmstatus
54
Pigeon Point Shelf Manager Command Line Interpreter
Threshold set successfully
88
# clia threshold
Pigeon Point Shelf Manager Command Line Interpreter
88
: LUN: 0, Sensor # 2 ("emulated temp")
Type: Threshold (0x01), "Temperature" (0x01)
Lower Non-Critical Threshold, Raw Data: 0x03, Processed Data:
3.000000 degrees C
Lower Critical Threshold, Raw Data: 0x14, Processed Data:
20.000000 degrees C
Lower Non-Recoverable Threshold, Raw Data: 0xfb, Processed
Data: -5.000000 degrees C
Upper Non-Critical Threshold, Raw Data: 0x63, Processed Data:
99.000000 degrees C
Upper Critical Threshold, Raw Data: 0x50, Processed Data:
80.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x5a, Processed
Data: 90.000000 degrees C
clia shmstatus [-v]
This command displays the Shelf Manager status in redundant configurations: Active or
Backup. In verbose mode (using -v) the command displays more information including
the status of the Shelf FRU Info, status of the Remote Management Control Protocol
(RMCP) interface, and state of the backup Shelf Manager (if the Shelf Manager being
queried is the active one).
The command output includes a Ready For Operation flag that shows Yes:
For the active Shelf Manager if the active shelf manger finds valid shelf FRU
information and successfully initializes its RMCP interface.
For the backup Shelf Manager if the backup shelf manager successfully receives
redundancy state information from the active Shelf Manager.
Example verbose mode output for an active shelf manager:
# clia shmstatus -v
Pigeon Point Shelf Manager Command Line Interpreter
Host: "Active"
Ready For Operation: Yes
Detailed State Flags: "Shelf FRU Found" "Backup Healthy" "Initial
Update Sent" "RMCP Up"