Clia; Exit/Quit; Fans - Fortinet FortiGate-5060 Chassis Manual

Hide thumbs Also See for FortiGate-5060:
Table of Contents

Advertisement

clia

clia

exit/quit

fans

36
Table 10: PICMG FRU states
FRU state
Description
Not Installed
M0
Inactive
M1
Activation Request
M2
Activation in Progress
M3
FRU Active
M4
Deactivation Request
M5
Deactivation in Progress
M6
Communication Lost
M7
clia
Start the CLI interactive mode. Using the interactive mode you can enter commands
without including the clia prefix.
exit
quit
If you start the CLI interactive mode by entering clia without any parameters you can
enter exit or quit to exit interactive mode.
clia fans [-v] [ <IPMB_address> [ <FRU_device_ID> ] ]
Display information about the specified fan FRU. If <FRU_device_ID> is omitted, the
command displays information about all fan FRUs controlled by the IPM controller at the
specified address. If <IPMB_address> is also omitted, the command displays
information about all fan FRUs known to the shelf manager. The command displays the
following information for each fan:
IPMB address and FRU device ID
Current Level
Minimum Speed Level
Maximum Speed Level
# clia fans
# clia fans
20: FRU # 4
Current Level: 8
Minimum Speed Level: 1, Maximum Speed Level: 15 Dynamic minimum fan
level: 8
20: FRU # 3
Current Level: 8
Minimum Speed Level: 1, Maximum Speed Level: 15 Dynamic minimum fan
level: 8
Using the shelf manager CLI
FortiGate-5060 Chassis Guide
01-400-129494-20110912
http://docs.fortinet.com/
Feedback

Advertisement

Table of Contents
loading

Table of Contents