FortiGate-5060 shelf alarm panel

Shelf Manager fan and power control

FortiGate-5060 shelf alarm panel
12
The FortiGate-5060 shelf managers monitor the internal temperature of the
FortiGate-5060 chassis and adjust the operating speed of the FortiGate-5060 chassis
cooling fans as required.
When the chassis is first powered on all cooling fans run at full speed. Once the shelf
manager is up and running, the shelf manager reduces cooling fan speeds to maintain an
optimum temperature in the chassis. If shelf managers are not installed or not operating
correctly the FortiGate-5060 chassis cooling fans always operate at full speed.
The FortiGate-5060 shelf alarm panel (SAP), located at the top of the FortiGate-5060 front
panel, provides LED indicators of FortiGate-5060 alarms, a telco alarm connector, an
alarm LED reset button, and console access to the FortiGate-5060 shelf managers. The
LED alarm indicators include critical, major, and minor alarms as well as three user
defined alarms.
The alarm LED reset button (RESET) on the shelf alarm panel activates the Alarm Cutoff
(ACO) state. When ACO is activated, the active alarm LEDs blink and all of the alarm
relays are deactivated.
Figure 4: FortiGate-5060 shelf alarm panel front panel
Minor Alarm (MIN) (Amber)
Major Alarm (MAJ) (Red)
Critical Alarm (CRT) (Red)
5000SAP
SERIAL
1
Retention
Screw
SERIAL 1 (Primary
Shelf Manager)
User 3 Alarm (Amber)
User 2 Alarm (Amber)
User 1 Alarm (Amber)
RESET
Alarm
Telco Alarm
LED Reset
Interface
Button
SERIAL 2 (Secondary
Shelf Manager)
http://docs.fortinet.com/
FortiGate-5060 chassis
SERIAL
2
FortiGate-5060 Chassis Guide
01-400-129494-20110912