Data Amount And Memory Capacity - Fronius IG-TL 3.0 Operating Instructions Manual

Inverter for grid-connected photovoltaic systems
Table of Contents

Advertisement

Structure of the CSV file:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Data amount and
One USB stick with a memory capacity of 128 MB, for example, can record logging data at
memory capacity
a logging interval of 5 minutes for approx. 7 years.
CSV file
CSV files can store only 65535 rows (data records) (up to Microsoft® Excel version 2007,
afterwards there is no limit).
At a logging interval of 5 minutes, the 65536 rows are written within approx. 7 months (CSV
data size of approx. 8 MB).
To avoid loss of data, the CSV file should be backed up to a PC within these 7 months and
deleted from the USB stick. If the logging interval is set longer, this time frame is extended
accordingly.
50
(1)
(5)
ID
Inverter no.
Inverter type (DATCOM code)
Logging interval in seconds
Energy in watt-seconds with reference to the logging interval
Averages over the logging interval
Additional information
(2)
(3)
(6)
(4)
(7)