8.4

Alarm and warning table

Name
Abbr.
UNDER VOL-
10
uv
TAGE
MEMORY ER-
12
ME1
ROR 1
CE
EXT. CLOCK
13
ERROR
15
ME2
MEMORY ER-
ROR 2
BE
BOARD ERROR This alarm occurs if any part of
17
NO SIGNAL
20
21
NS2
NO SIGNAL
ENC.)
22
Description
This alarm occurs if input sup-
ply voltage goes down below the
specified level, or if instan-
taneous power failure lasting
for over 15ms occurs.
This alarm occurs if read from,
or write to internal memory for
controller system control does
not go normally (memory is
checked when the control system
is turned on).
This alarm occurs if error oc-
curs in access time (2-ports me-
mory), due to failure in exter-
nal clock, during NC mode opera-
tion with FR-SFJ connected to
M300 CNC through bus line.
This alarm occurs if 2-port me- A
mory for data communication
(when FR-SFJ is connected to'
M300 series CNC) does not func-
tion properly.
control card is not in good con-
dition.
This alarm occurs if signal from
motor built-in encoder is not at
normal level.
This alarm occurs if signal from
encoder for oriented spindle
stop is not input, or not at
normal level.
Motion
(Note)
A
A
A
A
A