First Step Of Troubleshooting - Mitsubishi FREQROL-SFJ Maintenance Manual

Ac spindle drive
Table of Contents

Advertisement

13. Is supply voltage normal?
Does it change from time to time?
8.2

First step of troubleshooting

Perform the following check:
Power supply voltage should be 2OOV+:$, 50/60Hz, or
In any case, it should not go down below -15% of 200V.
o Check if the supply-voltage drops at a specific time
everyday.
Check if the supply voltage drops at start of a speci-
fic machine in the factory.
Are the peripheral control devices or functions in good
condition?
o Are the NC and programmable controller wired proper-
ly?
o Visually check cables and other components for condi-
tion.
Is temperature inside and outside the control equpment
below 55OC?
Visually check the control equipment.
o Cards, circuit patterns, etc.
o Looseness of wire, damage, foreign matter, etc.
All control power supplies of IM-PW2 card meet the
specified voltages?
O u t p u t
v o l t a g e ,
n o m i n a l
Check pin
Common
N o r m a l
v o l t a g e
P 1 5
C H 2 8
c H 3 4
c H 3 5
C H 2 7
P 2 4
C H 3 6
C H 2 6
C H 3 5