check in accordance with (6).
(8) "Speed detection" signal is not output (for DIO interface
with NC) . . . .
Cause
Trouble with
card SFJ-CA1
(9) "Zero speed" signal is not output (for DIO interface with
Cause
Trouble with
card SFJ-CA1
Speed range cannot be changed (for DIO interface with NC)
put properly.
Perform check in accordance with (8) an (9).
Speed cannot be increased over a certain speed . . . . .
Check the maximum speed setting.
Check if "override" (speed clamp) signal is input.
Check if leading of the load meter is excessively large
(check the load conditions).
Checkup
Check that "speed detection"
flag. (external output in
DIAGNOSIS mode) turns on
when motor speed reaches the
preset speed.
If the flag does not turn on,
the output circuit is defec-
tive.
Checkup
Check that "zero speed" flag
(external output in DIAGNO-
SIS mode) turns on when mo-
tor speed is below 25rpm or
If the flag turns on, the
output circuit is defective.
Remedv
Replace the card
Remedy
Replace the card