Speed Ref - ABB ACS850 Manual

Machinery drive
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

170 Parameters
No.
Name/Value
20.08
Minimum torque1
-1600.0 ... 0.0%
20.09
Maximum torque2
AI1 scaled
AI2 scaled
FBA ref1
FBA ref2
D2D ref1
D2D ref2
PID out
Max torque1
Pointer
20.10
Minimum torque2
AI1 scaled
AI2 scaled
FBA ref1
FBA ref2
D2D ref1
D2D ref2
PID out
Neg max torq
Min torque1
Pointer
20.12
P motoring lim
0.0 ... 1600.0%
20.13
P generating lim
0.0 ... 1600.0%
21

21 Speed ref

21.01
Speed ref1 sel
Zero
AI1 scaled
AI2 scaled
Freq in
Description
Defines minimum torque limit 1 for the drive (in percent of the
motor nominal torque). See parameter
Minimum torque 1.
Defines the source of maximum torque limit 2 for the drive (in
percent of the motor nominal torque). See parameter
Torq lim
sel.
02.05 AI1 scaled
(see page 105).
02.07 AI2 scaled
(see page 105).
02.26 FBA main ref1
(see page 109).
02.27 FBA main ref2
(see page 109).
02.32 D2D ref1
(see page 110).
02.33 D2D ref2
(see page 110).
04.05 Process PID out
(see page 115).
20.07 Maximum torque1
Value pointer setting (see
102).
Defines the source of minimum torque limit 2 for the drive (in
percent of the motor nominal torque). See parameter
Torq lim
sel.
02.05 AI1 scaled
(see page 105).
02.07 AI2 scaled
(see page 105).
02.26 FBA main ref1
(see page 109).
02.27 FBA main ref2
(see page 109).
02.32 D2D ref1
(see page 110).
02.33 D2D ref2
(see page 110).
04.05 Process PID out
(see page 115).
-20.09 Maximum torque2
20.08 Minimum torque1
Value pointer setting (see
102).
Defines the maximum allowed power fed by the inverter to the
motor in percent of the motor nominal power.
Maximum motoring power.
Defines the maximum allowed power fed by the motor to the
inverter in percent of the motor nominal power.
Maximum generating power.
Speed reference source and scaling settings; motor
potentiometer settings.
Selects the source for speed reference 1. See also parameter
21.03 Speed ref1
func.
Zero speed reference.
02.05 AI1 scaled
(see page 105).
02.07 AI2 scaled
(see page 105).
02.20 Freq in
(see page 105).
20.06 Torq lim
(see page 169).
Terms and abbreviations
(see page 170).
(see page 170).
Terms and abbreviations
FbEq
sel.
10 = 1%
20.06
1073742341
1073742343
1073742362
1073742363
1073742368
1073742369
1073742853
1073746951
on page
-
20.06
1073742341
1073742343
1073742362
1073742363
1073742368
1073742369
1073742853
1073746949
1073746952
on page
-
10 = 1%
10 = 1%
0
1073742341
1073742343
1073742356

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents