Table 9-10
Input voltage
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current
Power loss
Dimensions WxHxD (with spacers)
Weight
9.2
PP 72/48D PN
9.2.1
Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting
digital input/outputs as part of an automation system based on PROFINET IO.
The module has the following important features:
● PROFINET IO connection (max. 100 Mbits/s)
● 72 digital inputs and 48 digital outputs
● On-board status display via 2 diagnostic LEDs
● The 3 plug-in connectors for the digital inputs and outputs are 50-pin terminal posts for
● Terminal strip converters can be used, or the direct connection of distribution boards, for
An external power supply unit (24 V DC) is required to supply the module and the digital outputs.
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Electrical and mechanical data
connecting ribbon cables.
example, is possible.
Connectable components
2
Open-circuit ventilation
Vertical
at the housing with M5 screw Torx / 3 Nm
24 V DC (20.4 – 28.8)
3.35 A
15 W
25 x 414 x 272 mm
2.58 kg
9.2 PP 72/48D PN