Siemens SINUMERIK 840D sl Manual page 79

Sinumerik 840d sl type 1b ncu 7x0.3 pn, ncu 7x0.3b pn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Note
The measuring sockets should be used exclusively for servicing purposes.
The measurements may only be carried out by appropriately trained specialists.
Interface assignments
Table 7-32
Socket
T0
T1
T2
M
The measuring sockets are only suited for banana plugs with a diameter of 2 mm.
Test socket position
Figure 7-15
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Measuring sockets T0, T1, T2
Function
Technical data
Test socket 1
Resolution: 8 bit.
Load current: max. 3 mA
Measuring socket 2
continuous short-circuit-proof
Measuring socket 3
The reference potential is terminal M
Ground
Arrangement of the measuring sockets on the lower side of the NCU
Connecting
7.11 Measuring sockets