Technical Data - Siemens SINUMERIK 840D sl Manual

Sinumerik 840d sl type 1b ncu 7x0.3 pn, ncu 7x0.3b pn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connectable components
9.3 PP 72/48D 2/2A PN
Value
Cause
byte 1
6
Range exceeded at the
inputs
7
Range exceeded at the
outputs
The analog outputs retain their last specified value.
1)
Diagnostics via status bytes 0/1
In status byte 0, the set operating modes are reflected e.g. "0x55" if control byte 0 = 0x55 has
been specified (voltage on all channels).
In the event of an error, the error bit is set in status byte 1 (bit 7). In the event of an error in
one channel, all channels are deactivated.
Table 9-69
Input image of analog inputs (excerpt)
Byte
Bit7
m+0
0
m+1
Error bit
9.3.6

Technical data

Table 9-70
Safety
Degree of protection
Protection class
Approvals
Electrical data
Rated voltage
Rated current
Power consumption at rated load
Power loss
Mechanical data
Dimensions WxHxD
Weight, approx.
For detailed technical data relating to the inputs and outputs, see the "Connecting" chapter.
X111, X222 and X333 digital inputs/outputs (Page 124)
Analog X3 inputs/outputs (Page 130)
144
Effect
Bit6
Bit5
0
0
0
0
Technical data of the I/O module
Bit4
Bit3
0
0
0
0
IP 00 according to EN 60529
III; DVC A, (PELV) acc. to EN 61800-5-1
cULus, CE
24 V DC
0.7 A
19 W (without digital outputs)
18 W
150 x 300 x 35 mm
0.9 kg
Remedy
Check input circuit and adjust, if required.
Correct the values in the user program.
Bit3
Bit1
0
0
0
0
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Bit0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents