Spare Parts/Accessories
10.1 Replacing the dual fan/ battery module
4. Connect the cable plug connector of the new battery to the mating connector in the dual
5. Tilt the dual fan/battery module forwards at an angle with the open side facing up (battery
6. Push the plastic guide into the cutouts on the underside of the NCU.
7. Tilt the dual fan/battery module up until the front interlock snaps into place. The electrical
156
fan/battery module and push the battery in.
Figure 10-1
Battery replacement in the dual fan/battery module
visible).
connection between the dual fan/battery module and the NCU is established automatically.
Note
The dual fan/battery module can be replaced during operation. If you choose to do this,
remember that the NCU can only be operated for a maximum of 1 minute without fans. If
this time is exceeded, it will shut itself down.
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1