Diagnostics Via Input Image - Siemens SINUMERIK 840D sl Manual

Sinumerik 840d sl type 1b ncu 7x0.3 pn, ncu 7x0.3b pn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connectable components
9.3 PP 72/48D 2/2A PN
Table 9-64
Measured values and responses in the temperature measurement operating mode
Address
Operating mode
QB72
Format
QB73
Value
QW76
Value
QW78
Operating mode
IB72
Format
IB73
Value
IW76
Value
IW78
Diagnostics
IB50
IB51
PNFault LED
Troubleshooting
9.3.5.5

Diagnostics via input image

Table 9-65
Diagnostics input image
Byte
Bit7
d+0
count_2
d+1
Table 9-66
Bit
7
6
5
4
3
2
1
0
142
Incorrect operating mode
16#AA
16#1
-
-
16#AA
16#81
-
-
16#2
16#3
on
Deactivating/activating
Bit6
Bit5
count_1
count_0
Messages in byte 0
Signal name
Message
count_2
alive and well 2
count_1
alive and well 1
count_0
alive and well 0
T_Alarm_2
Temperature not within the operating temperature range defined for the
module
T_Alarm_1
Critical temperature exceeded
Diag_2
Overload DO byte 5/4
Diag_1
Overload DO byte 3/2
Diag_0
Overload DO byte 1/0
Pt100
Bit4
Bit3
T_Alarm_2
T_Alarm_1
Status_1
Resistor is not connected
16#0F
16#1
-
-
16#0F
16#81
-
-
16#2
16#6
on
Deactivating/activating
Bit3
Bit1
Diag_2
Diag_1
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Bit0
Diag_0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents