Setting The Factory Defaults; Registration; Registering The Gsmvlp4G - Honeywell GSMVLP4G Installation And Programming Manual

Gsm module with 2-way voice
Table of Contents

Advertisement

Setting Factory Defaults
To reset the programming options to factory-default values, press [ESC] at the "Exit Prog Mode?"
prompt.
Press [Y] to reset factory default values.
Set Default?
Y/N_
Press [N] to cancel this function.
If you press [Y], all programmed values are reset to the original factory settings.
IMPORTANT NOTE:
THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED.
After pressing [Y], the Create Password prompt appears (see Programming step 4).

REGISTRATION

Registering the GSMVLP4G

Once you have initialized and programmed the GSMVLP4G, it must be registered to enable the
account. An unregistered GSMVLP4G is indicated on the Status Display as: Status lit, Message slow
blinking, and Fault not lit.
Figure 6 – Unregistered GSMVLP4G Status Display In Normal Operation
Throughout this document, the following key is used to describe LED state:
Upon completion of the registration process, a GSMVLP4G transmits a registration message and
receives a registration validation indicating that the account is now enabled. Wait for the "Registration
Success" message to appear.
The "Registration Success" message is only displayed when the 7720P Programming
Tool is used for registration.
You can register the GSMVLP4G by one of the following methods:
Through the AlarmNet Direct website
Through the use of the Test Message/Registration Switch
Through the use of a 7720P Programming Tool
By phone
Figure 7 – LED Key
– 14 –