Download  Print this page

Glossary; Specifications - Honeywell GSMVLP4G Installation And Programming Manual

Gsm module with 2-way voice
Hide thumbs

Advertisement

GLOSSARY

AES – Advanced Encryption Standard
ECP – Enhanced Console Protocol, which is a proprietary communications bus used in
Honeywell control panels for wiring additional keypads and peripheral devices; consists of a
four-wire data bus (power+/-, data in/out).
GPRS – (General Packet Radio Service)
GSM – Global System for Mobile communications, which is an international standard for
digital mobile phone systems used for cellular communication.
IMEI – International Mobile Equipment Identity number
MAC Address – Media Access Code; located on the module label.

SPECIFICATIONS

Physical
Dimensions: 5.625" x 2.25"
Electrical
Input Voltage: 12VDC (powered by the Lynx Plus/ReadyGuard Plus Series Control)
(Range: 5.5 VDC-12 VDC)
Quiescent Current: 40mA
Peak Current During Transmit: 650mA
Environmental
Operating temperature: -20ºC to +55ºC, for ULC installations 0ºC to +49ºC
Storage temperature: -40º to +70ºC
Humidity: 0 to 95% relative humidity, non-condensing
Altitude: to 10,000 ft. operating, to 40,000 ft. storage
RF
Frequency Bands: Plug-In Style Module
Output Power:
2G
GSM/GPRS/EDGE
3G/4G UMTS/HSPA+
Surface Mount Style Module
2G
GSM/GPRS/EDGE
3G/4G UMTS/HSPA+
2G
GPRS
+33dBm, GMSK modulation
Edge
+27dBm, 8-PSK modulation
3G
UMTS
+24dBm, QPSK modulation
WCDMA
4G
HSPA+
+24dBm, 64 QAM modulation
WCDMA
– 23 –
Quad Band 850/900/1800/1900 MHz
Band V, Band II, Band IV
Quad Band 850/1900 MHz
Band V, Band II