Technical Specification - Vent-Axia 405215 Advance S Installation & Commissioning Manual

Sentinel kinetic advance mvhr
Hide thumbs Also See for 405215 Advance S:
Table of Contents

Advertisement

Technical Specification

Performance
Airflow
Sound levels (@ 3 m)
Power
AC Voltage Input
AC Frequency Input
Supply Fuse
Product Fuse
Rated Power
Physical
Height (excl. spigots)
Width
Depth
Weight
Spigot diameter
Condensate pipe
diameter
Environmental
IP Rating
Operating Temperature
Air Intake Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Software Version
Sentinel Kinetic Advance MVHR Installation & Commissioning Instructions PN 408651
Sentinel Kinetic Advance S
3
Maximum, FID, 115 l/s (414 m
/h)
Low
default 20%
Normal default 30%
Boost
default 50%
Purge
default 100%
See website for full sound spectrum
220-240 V AC (single phase)
3 A (located in fused spur)
2 A (located on main PCB)
Technical Data
Sentinel Kinetic Advance SX
Low
default 15 l/s (54 m
Normal default 25 l/s (90 m
Boost
default 40 l/s (144 m
Purge
default 90 l/s (324 m
See website for full sound spectrum
50 Hz nominal
190W (max.)
760 mm
660 mm
443 mm
27 kg
125 mm
22 mm or 32 mm
IPX2
-20C to +45C
As above
0% to 95% RH
-20C to +45C
0% to 95% RH
V7
3
/h)
3
/h)
3
/h)
3
/h) @300pa
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

405216 advance sx

Table of Contents