8.2 ELECTRICAL / GENERAL SPECIFICATIONS (cont.)
ENCLOSURE
IP20
NEMA1/IP20
IP54
PC CONNECTION USB CONNECTOR
FOR INVERTER
PROGRAMMING

8.2.1 Codes and Standards

SAFETY
STANDARDS
ELECTROMAGNETIC
COMPATIBILITY (EMC)
MECHANICAL
STANDARDS
Inverters without Nema1 kit.
Inverters with Nema1 kit (KN1E-01 or KN1E-02).
Rear part of the inverter (external part for flange mounting).
USB standard Rev. 2.0 (basic speed);
Type B (device) USB plug;
Interconnection cable: standard host/device shielded USB cable.
UL 508C - Power conversion equipment.
UL 840 - Insulation coordination including clearances and creepage distances for electrical
equipment.
EN61800-5-1 - Safety requirements electrical, thermal and energy.
EN 50178 - Electronic equipment for use in power installations.
EN 60204-1 - Safety of machinery. Electrical equipment of machines. Part 1: General
requirements.
Note: The final assembler of the machine is responsible for installing an safety stop device
and a supply disconnecting device.
EN 60146 (IEC 146) - Semiconductor converters.
EN 61800-2 - Adjustable speed electrical power drive systems - Part 2: General
requirements - Rating specifications for low voltage adjustable frequency AC power drive
systems.
EN 61800-3 - Adjustable speed electrical power drive systems - Part 3: EMC product
standard including specific test methods.
EN 55011 - Limits and methods of measurement of radio disturbance characteristics of
industrial, scientific and medical (ISM) radio-frequency equipment.
CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment -
Electromagnetic disturbance characteristics - Limits and methods of measurement.
EN 61000-4-2 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 2: Electrostatic discharge immunity test.
EN 61000-4-3 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 3: Radiated, radio-frequency, electromagnetic field immunity test.
EN 61000-4-4 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 4: Electrical fast transient/burst immunity test.
EN 61000-4-5 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement
techniques - Section 5: Surge immunity test.
EN 61000-4-6 - Electromagnetic compatibility (EMC)- Part 4: Testing and measurement
techniques - Section 6: Immunity to conducted disturbances, induced by radio-frequency
fields.
EN 60529 - Degrees of protection provided by enclosures (IP code).
UL 50 - Enclosures for electrical equipment.