WEG CFW-11 User Manual page 76

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Option Kits and Accessories
The code and model of each availabe accessory is presented in the table 7.2. The accessories can be ordered
separately and will be shippe in an individual package containing the components and the manual with detailed
instructions for the product installation, operation, and programming.
ATTENTION!
Only one module can be fitted at once in each slot (1, 2, 3, 4, or 5).
WEG Part
Name
Number
11008162
IOA-01
11008099
IOB-01
11008100
ENC-01
11008101
ENC-02
11008102
RS485-01
11008103
RS232-01
11008104
RS232-02
11008105
CAN/RS485-01 CAN and RS-485 interface module (CANopen / DeviceNet / Modbus).
11008106
CAN-01
11008911
PLC11-01
11008107
PROFDP-05
11008158
DEVICENET-05
10933688
ETHERNET/IP-05 Ethernet/IP interface module.
11008160
RS232-05
11008161
RS485-05
11008912
MMF-01
11008913
HMI-01
11010521
RHMIF-01
11010298
HMID-01
10960842
KN1E-01
10960850
KN1E-02
10960844
PCSE-01
7
10960847
CCS-01
10960846
CONRA-01
(1) Refer to the PLC Module Manual.
(2) Refer to the Anybus-CC Communication Manual.
(3) Refer to the Software Manual.
(4) Use DB-9 pin, male-to-female, straight-through cable (serial mouse extension type) for connecting the keypad to the inverter or Null-Modem
standard cable. Maximum cable length: 10 m (33 ft).
Examples:
- Mouse extension cable - 1.80 m (6 ft); Manufacturer: Clone.
- Belkin pro series DB9 serial extension cable 5 m (17 ft); Manufacturer: Belkin.
- Cables Unlimited PCM195006 cable, 6 ft DB9 m/f; Manufacturer: Cables Unlimited.
(5) Refer to the section 8.4 for more details.
7-4
Table 7.2 - Accessory models
Control accessories for installation in the Slots 1, 2 and 3
IOA module: 1 voltage/current analog input (14 bits); 2 digital inputs; 2
voltage/current analog outputs (14 bits); 2 open-collector digital outputs.
IOB module: 2 isolated analog inputs (voltage/current); 2 digital inputs; 2
isolated analog outputs (voltage/current) (the programming of the outputs
is identical as in the standard CFW-11); 2 open-collector digital outputs.
5 to 12 Vdc incremental encoder module, 100 kHz, with an encoder
signal repeater.
5 to 12 Vdc incremental encoder module, 100 kHz.
RS-485 serial communication module (Modbus).
RS-232C serial communication module (Modbus).
RS-232C serial communication module with DIP-switches for
programming the microcontroller FLASH memory.
CAN interface module (CANopen / DeviceNet).
PLC module.
Anybus-CC accessories for installation in the Slot 4
ProfibusDP interface module.
DeviceNet interface module.
RS-232 (passive) interface module (Modbus).
RS-485 (passive) interface module (Modbus).
Flash Memory Module for installation in the Slot 5 – Factory Settings Included
FLASH memory module.
Stand-alone keypad, blank cover, and frame for remote mounted keypad
Stand-alone keypad.
(4)
Remote keypad frame kit (IP56).
Blank cover for the keypad slot.
Nema1 kit for the frame size E models CFW11 0142 T 2, CFW11 0105 T 4
and CFW11 0142 T 4 (standard for N1 option).
Nema1 kit for the frame size E models CFW11 0180 T 2, CFW11 0211 T 2,
CFW11 0180 T 4 and CFW11 0211 T 4 (standard for N1 option).
Kit for power cables shielding - frame E (included in the standard product).
Kit for control cables shielding (included in the standard product).
Control rack (containing the CC11 control board).
Description
Miscellaneous
(5)
Identification
Parameters
Slot
P0027
P0028
1
FD--
1
FA--
2
--C2
2
--C2
3
----
3
----
3
----
3
----
3
----
1, 2 and 3
----
--xx
4
----
--xx
4
----
--xx
4
----
--xx
4
----
--xx
4
----
--xx
5
----
HMI
-
-
-
HMI
-
-
-
-
-
(5)
-
-
-
-
-
-
----
----
----
----
CE--
CC--
CC--
CA--
CD--
(1)(3)
(2)(3)
(2)(3)
(2)(3)
(2)(3)
(2)(3)
--xx
(3)
-
-
-
-
-
-
-
-

Hide quick links: