Self-Assembled Cables - Siemens ASM 456 Operating Instructions Manual

Interface module
Hide thumbs Also See for ASM 456:
Table of Contents

Advertisement

Table A- 3
Note:
Readers with D-sub connectors must be supplied with 24 VDC via an additional connector.
A.1.2

Self-assembled cables

A write/read connector plug with screw-on clamps is provided for users who want to
individually pre-assemble their own cables (refer to the relevant system manual). Cables and
write/read connector plugs can be ordered from the MOBY catalog.
The pin assignment is listed in the following table.
Cable structure
You will need cables of the following specifications for self-assembled cables:
7 x 0.25 mm
LiYC11Y 7 x 0.25
ASM 456 interface module
Operating Instructions, 07/2015, J31069-D0162-U001-A6-7618
Connecting cable M12 ↔ sub-D 9-pin
M12 connector (male)
2
Sub-D connector (female)
1
-
2
5
3
7
4
3
5
2
6
6
7
-
8
1, 8
Appendix
A.1 Connecting cables
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents