Input parameters for ASM 456 with FC 56
The assignment is made in UDT 10.
Table 5- 3
Input parameters for ASM 456 with FC 56
Address
Name
+0.0
ASM_address
+2.0
ASM channel
+8.0
MDS IO control
+9.0
ECC_mode
+9.2
priority_RW
+9.3
priority_RWD
+10.0
MOBY mode
+11.0
scanning_time
+12.0
SLG_number
+14.0
distance_limiting
+15.0
multitag
+16.0
field ON control
+17.0
field ON time
ASM 456 interface module
Operating Instructions, 07/2015, J31069-D0162-U001-A6-7618
5.3 Parameter assignment with FB 45/55 and FC 56
Permissible values
0, 4, 8, 12, ...
1
B#16#0, 1, 4, 5
TRUE, FALSE
TRUE, FALSE
TRUE, FALSE
B#16#1, 4, 5, 6
MOBY I:
B#16#00 ... FF
MOBY U:
B#16#00 ... C8
B#16#0001 ... FFFF
B#16#05, 0A, 0F, 14,
19, 1E, 23
MOBY I:
B#16#1
MOBY U:
B#16#01 ... 0C
B#16#0, 1, 2
B#16#00 ... FF
Comment
Each ASM 456 occupies four bytes of I/O
in the I/O area of the controller.
1 channel per ASM
Enable/disable presence check
TRUE is only permitted
when MOBY mode is set to 1
MOBY I/U
A value not equal to 00 is only of any
use if MOBY_mode has been parameterized
accordingly
With FFFF, the test function is switched
on
MOBY U
MOBY I/U
MOBY U
MOBY U
Parameterization
37