Upgrade Procedure - Polycom RMX 1000 Getting Started Manual

Hide thumbs Also See for RMX 1000:
Table of Contents

Advertisement

Upgrade Procedure

Upgrading from Version 1.1 to Version 2.1
Please don't restart the system until both the two required packages
are uploaded into RMX 1000 successfully. Otherwise the upgrade
will failed and cause the unavailability of the Web UI. If that
happens, you can use the RMX 1000 Rescue utility provided with the
device to restore the upgrade. For details please refer to System
Recovery.
1
Download the required software Version 2.1 (xx-File Sys-
tems-xx.ppm and xx-Kernel Systems-xx.ppm) from Polycom web
site.
2
In the Upgrade System page, install the two upgrade packages of
software Version 2.1.
3
Read the License Agreement and select I Agree if you accept the
terms and conditions.
4
Click Open to select the Kernel System package (.ppm) in the folder
where Version 2.1 files are saved and click Upload File.
5
The system displays "Software upload successfully - reboot system
to activate new version now or later?", click Reboot Later, do not
restart the system.
6
Continue to upload the File System package as described in Step 4.
7
When prompted whether to restart the system, click Reboot Now
to restart your system.
This upgrade requires the installation of an upgrade activation Key.
After the system reboot, you need to log into the Web UI to activate the
system. Go to Activating the Upgraded System section for further opera-
tions.
If the upgrade failed due to restarting the system by mistake, move on
to the following section for rescuing information.
6